Landed house pressure diagnosis · Singapore
Low water pressure in a landed house — pump or supply?
In a Singapore landed house, weak pressure is usually not the mains supply: check whether every tap is weak (incoming supply or a failed booster) or only the upstairs bathrooms (pipe sizing, a waterlogged pressure vessel or a worn impeller). A pump that runs continuously but delivers little is the classic sign. Diagnosis from S$120.
- Diagnosis from S$120
- Mon–Sat 08:00–17:00, not 24/7
- PUB plumber WS16882018
- Booster, transfer and pressure vessel
Start with one tap, not with the pump
Most landed houses have a tank and their own booster set, so the pressure you feel at the shower is set by the pump, not by the pressure PUB delivers at the gate. That is why the first reading has to be taken as close to the incoming main as possible — before the pump has done anything.
Weak at the tap nearest the incoming main
The loss is upstream of your pump set. That is a supply-side problem, not a pump problem — no pump you buy will add pressure that was never there. It is the case for going back to the water authority rather than to a contractor.
Strong there, weak upstairs
The supply is fine and the loss is inside the house: a booster that is not building pressure, a pressure vessel that has lost its air charge, a restricted strainer, or a long run of undersized pipe to the upper floor.
Where you notice it, and what it usually means
| What you notice | What it usually means | What a competent technician tests |
|---|---|---|
| Every tap weak, including the one near the gate | Incoming supply, not the pump | Static and running pressure at the incoming main, before the pump set |
| Only the upstairs bathrooms or the furthest tap weak | Long or undersized branch run, or a booster losing pressure under load | Running pressure at the far outlet, pipe diameter and the number of fittings |
| Pump runs constantly, pressure never builds | Waterlogged pressure vessel (air charge gone) or a worn impeller | Vessel pre-charge, a drawdown test, flow against the pump curve |
| Pump cuts in and out rapidly | Pressure vessel charge lost, or the pressure switch is out of adjustment | Pre-charge, cut-in and cut-out settings, and whether the switch is sticking |
| Fine on one outlet, drops when a second opens | The duty point was sized for one outlet at a time | Simultaneous flow test against rated flow, then the pump curve |
| Pressure fades over weeks; water still clear | Blocked suction strainer, or a partly closed valve left that way after a repair | Strainer, valve position, suction lift and air lock |
Updated 14 Nov 2026
What happens when you engage AOT
- Send photos. The pump set, the pressure vessel, the incoming main and the valve positions. A photo of the pump nameplate saves a second visit, because the curve is on it.
- We measure, in this order. Static and running pressure at the incoming main, then at the pump outlet, then at the furthest outlet. Diagnosis from S$120.
- Written scope and price before parts. A strainer clean, a vessel re-charge, a pressure switch or a new duty point are four different jobs with four different answers. You get the finding and the price before work starts.
- Prove it before we leave. Two outlets running at once, pressure read at the furthest one, then a full pump cycle to confirm it is not short cycling.
Repair, re-charge or replace
A pressure vessel that has lost its air charge is a re-charge, provided the bladder still holds. A blocked strainer or a wrongly set pressure switch is a repair. A worn impeller on an old set, or a duty point that was never right for the house, is a replacement — and a replacement is quoted from the duty point and suction conditions, never from a photo alone.
If the weak pressure started after plumbing work — a heater change, a new bathroom, a valve left part-closed — say so when you send the photos. That single fact often ends the diagnosis before anyone opens the pump.
Questions people ask before booking
Is my low water pressure the PUB supply or my pump?
Test it at the incoming main first. If pressure is low at the tap nearest the incoming main, the problem is upstream of your pump set and the water authority should be called. If that tap is strong and the upstairs bathrooms are weak, the loss is inside the house: the booster set, the pressure vessel or the pipe run.
Why does the pressure drop only when two taps are open?
The pump was sized for one outlet at a time. Opening a second outlet moves the pump along its curve to a higher flow and a lower pressure. The fix is a larger duty point or a different control arrangement, not a higher pressure setting.
My pump runs all the time but the shower is still weak. Why?
Continuous running with little delivery is the classic sign of a waterlogged pressure vessel — the air charge is gone, so there is nothing to store — a worn impeller, or a restricted suction strainer. A drawdown test and a flow reading separate those three.
Can I just fit a bigger pump?
Not before the cause is known. A bigger pump will not fix a blocked strainer, a waterlogged vessel or a 13 mm branch run, and it can make short cycling worse. Sizing comes after the pressure reading, not instead of it.
How much is diagnosis, and when can you come?
Pump and pressure diagnosis starts from S$120, confirmed before any work begins. Hours are Monday to Saturday 08:00–17:00, closed Sunday and public holidays. This is not a 24-hour service.